AM.II.F.S8
SkillService a hydraulic system reservoir.
From the FAA library
- Chapter 12: Hydraulic & Pneumatic Power Systems › Hydraulic System Components › Reservoirs
When the system is pressurized, and the pointer lies between REFILL and FULL SYS PRESS, a marginal reservoir fluid level is also indicated. Reservoir Servicing Nonpressurized reservoirs can be serviced by pouring fluid directly into the reservoir through a filler ... filler well to strain out impurities as the fluid enters the reservoir. Many reservoirs also have a quick disconnect service port at the bottom of the reservoir. A hydraulic filler unit can be connected to the service port…
- Chapter 12: Hydraulic & Pneumatic Power Systems › Types of Hydraulic Fluids
instruction plate affixed to the reservoir or unit being serviced. The three principal categories of hydraulic fluids are: 1. Minerals. 2. Polyalphaolefins. 3. Phosphate esters. When servicing a hydraulic system, the technician must be certain to use the correct category…
- Chapter 12: Hydraulic & Pneumatic Power Systems › Hydraulic Fluid Contamination › Contamination Control
suspected problem. • Service system reservoirs to replace the fluid that was removed. Submit samples for analysis to laboratory. Contamination Control Filters provide adequate control of the contamination problem during all normal hydraulic system operations. Control of the size and amount ... contamination entering the system from any other source is the responsibility of the people who service and maintain the equipment. Therefore, precautions should be taken to minimize contamination during maintenance, repair, and service operations. If the system becomes contaminated…